Challenger Breaker Panel Bus Bar
The company at some point could have re labeled the.
Challenger breaker panel bus bar. Thank you to honor services for supplying the video. We also carry all of the replacement circuit breakers for these panels. Between the 1980 s to the 1990 s challenger panels were installed in hundreds of thousands of homes. You can see evidence of overheating at mid right bus bar by the discoloration.
Make offer challenger 3ph 208y 120v 225a powermaster panelboard prl1. Electrical panel bus overheats circuit breaker failures field reports. We are a newly formed company so our inventory is growing daily. Challenger 3ph 208y 120v 225a powermaster panelboard prl1.
We have circuit breaker testing capability thru 200 amp. They named their product challenger. Challenger was very similar in design to zinsco which brought speculation. We have a large assortment of zinsco sylvania and challenger bus bars dead front covers and meter parts.
But if the breaker doesn t trip the increasing current can cause the wires to overheat and even ignite. This article includes photographs of overheated challenger electric electrical panel components and cites a historical connection between challenger electric company and federal pacific electric. However the specific panel bus and breaker designs are different among those brands. Sunday march 1 2020.
The overheating causes cyclical expansion and contraction of the the bus bars creating a gap between the bus bar and breaker and consequent electrical arcing which has caused meltdown of the panel components in some cases. Challenger instant switchboard msp42 4sn 400 amp interior 240 208 120v 3p 4w. Over the years it was discovered that two types of circuit breakers manufactured by challenger were overheating under normal conditions at the connection point to the bus bar. Siemens 18 ge 12 eaton 8 square d 8 leviton 6 blackburn 2 arlington industries 1 connecticut electric 1 erico 1.
Free delivery with 45 order. Also you can verify this is a challenger panel by the sticker on the back right as well as the labels on the breakers. Eaton 21 terminal ground bar for type ch and type br panels model gbk2120 15 45 15 45. Set your store to see local.
Challenger panel overheat reports are not restricted to the use of challenger breakers in fpe panels but it is no surprise and no coincidence that challenger s manufacture and sale of fpe stab lok replacement circuit breakers would by itself produce a blizzard of panel failures bus overheats and circuit breaker no trip failures since. Challenger panel arcing video.