Chart Electrical Cable Size In Mm

Awg to metric conversion chart.
Chart electrical cable size in mm. Clive beesley switch electrical easy to order item arrived the day after as promised and delivery was free. For example 7 0 2 means 7 strands of wire each 0 2mm. Common sizes include 14 12 10 8 6 and 2 gauge wire. Wire gauge refers the physical size of the wire rated with a numerical designation that runs opposite to the diameter of the conductors in other words the smaller the wire gauge number the larger the wire diameter.
Now you can take the advantage of this calculator to do this job j you can also check the classical wire cable size calculator in awg calculating wire cable size formula for single phase circuits. Check back soon to download our mm to awg conversion pdf. The n gauge wire diameter d n in inches in is equal to 0 005in times 92 raised to the power of 36 minus gauge number n divided by 39. Values are for not more than three conductors in raceway or cable reference.
Cross section mm 2 approximate overall diameter mm current rating. Single phase amps three phase amps 1 5. Wire is sized by the american wire gauge awg system. In europe wire sizes are expressed in cross sectional area in mm and also as the number of strands of wires of a diameter expressed in mm.
Wire gauge calculations wire diameter calculations. What about other cable sizes. These tables of electrical service entry cable sizes electrical circuit wire diameters circuit ampacity allowable voltage drop wire size increase based on run length assist in determining the electrical service size or other required electrical wire sizes at buildings. Amperage amps versus wire cable size mm to awg ul486e assigned maximum ampere rating versus wire size for copper conductors.
These are mostly used for appliances and objects that require much more electrical power to operate or special use situations. Cable size current rating chart. The n gauge wire diameter d n in millimeters mm is equal to 0 127mm times 92 raised to the power of 36 minus gauge. Today we are here with another comprehensive copper and aluminum wire size calculator as we have discussed in detail the topic of how to calculate the proper wire size for electrical wiring.
Aside form the 3 most commonly used cable sizes of 1 1 5 and 2 5mm twin and earth there are in fact several other larger sizes of cable that include 4mm 6mm 10mm and 16mm. Awg to mm2 pdf. National electrical code ansi nfpa 70 1999. This table gives closest equivalent size cross references between metric and american wire sizes.
D n in 0 005 in 92 36 n 39. I wish all my dealings with suppliers were as efficient it would my life so. International standard wire sizes iec 60228 0 5 mm.